Reference Report
[REF9000-0022-E]
Application
Assembly line for construction machines
Country
USA
City
Clayton, North Carolina
Representative office
Conductix-Wampfler Inc. [USA]
Technical requirement[s]
Contactless power supply for Automated Guided Vehicle
Track length
337 m [2 track switches]
Number of vehicles
16 [+ 1 spare vehicle]
Additional information [vehicle]
Travel speed [Load]
5,5 m/min
Product
Additional product information
With iDAT for guidance, positioning and data transmission
Power
Generally the basic function of Floor systems is the same as that of other Inductive Power Transfer systems. But there are some additional or specific aspects to consider.
The cable loop must be installed in a way that complete coverage of the supply of vehicles along the entire travelling path is given. This way installed the cable routing also defines the travelling path of vehicles. With inductive track guidance it is possible to detect the magnetic field around the cabling and to supply a guidance signal to the vehicle control and to control so the movement of the vehicle. Unwanted and expensive guidance slots become obsolete this way. Various travelling paths can be defined. Switches, crossings, etc. are no problem. The pickup just needs to be placed so that it is exposed to the magnetic field in a sufficient way.